Vectrolink
BACnet Translator & MS/TP/IP Converter Coming Q1 2027

vBT-02

Bridge BACnet MS/TP field devices — sensors, actuators, meters — to BACnet/IP, so your BMS backbone can reach them without a middleware PC.

2× RS485
MS/TP↔IP
DIN-rail

What it does

Building automation systems increasingly run BACnet/IP as the backbone, but most field-level sensors, actuators and meters still speak BACnet MS/TP over RS485. vBT-02 sits between them and handles the protocol bridging.

⇄

MS/TP ↔ IP bridging

Exposes BACnet MS/TP devices on an RS485 trunk as BACnet/IP objects reachable from your BMS backbone — and the reverse, routing BACnet/IP commands down to MS/TP field devices.

⇅

Two independent field trunks

Two isolated RS485 channels, each an independent MS/TP trunk with its own baud rate — bridge two separate zones or vendor segments from a single unit.

☁

Manage devices from anywhere

No need to be on the local network or log in on-site. Vectrolink Cloud gives you secure access to the Web UI and REST API from any browser, anywhere with internet — no VPN, no port forwarding. Sold as a separate subscription to the vBT-02 device.

⟷

Same DIN-rail platform as vMT-02

Identical enclosure and mounting as the Vectrolink vMT-02. If you already run vMT-02 units on site, vBT-02 slots into the same rail, the same power budget, the same Cloud dashboard.

Use cases

Building automation

Field sensors → BMS backbone

A BMS controller runs BACnet/IP as its backbone protocol, but the VAV boxes and thermostats on a floor are wired MS/TP over RS485 — a common split in commercial buildings. vBT-02 bridges the floor trunk to the IP backbone without reprogramming either side.

Retrofit

Legacy MS/TP-only controllers

Older HVAC controllers often only ever shipped with an MS/TP port. vBT-02 gives them a path onto a modern BACnet/IP network without swapping the controller.

Multi-vendor sites

Two trunks, two vendor segments

Two independent RS485 channels mean a single vBT-02 can bridge two separate MS/TP trunks — useful when a retrofit project has controllers from different vendors on separate physical buses.

Remote monitoring

Off-site visibility

A mechanical room with no reliable local IT presence. vBT-02 tunnels the bridged data to Vectrolink Cloud so a technician can check status from a browser, anywhere.

Technical Specifications

RS485 Channels 2× galvanically isolated, fully independent (RS485-1, RS485-2)
Baud Rate 1 200 – 115 200 bps per channel, independently configurable
Parity None / Even / Odd per channel
Connectivity Wi-Fi 802.11 b/g/n 2.4 GHz · 10/100 Mbps Ethernet
Remote access Web UI and REST API accessible via Vectrolink Cloud when internet is available
Power Supply 10 – 24 V DC, < 3 W
Protection IP20 · Reverse-polarity protected
Temperature −20 °C to +70 °C operating
Housing DIN-rail (35 mm TS), 2-module width
Configuration Web UI · REST API

BACnet object/property mapping capacity will be published closer to release.

Interested in vBT-02?