Vectrolink
Modbus → BACnet Gateway Available now

vMBT-02

Bring Modbus RTU meters, heat pumps, drives and controllers into a BACnet building management system — up to 500 points as native BACnet objects, over BACnet/IP or BACnet MS/TP.

2× RS485
Modbus + BACnet
DIN-rail

What it does

Energy meters, heat pumps, frequency drives and air handling controllers often speak only Modbus, while the building management system speaks BACnet. vMBT-02 polls the Modbus devices on its RS485 channels and presents every value as a standard object of its own BACnet device — the BMS reads it, subscribes to changes and sends commands back, without a PC or middleware in between.

▦

Native BACnet objects

Each point becomes an Analog Input, Analog Value, Binary Input or Binary Value with its own name, engineering units and COV increment. Modbus data types U16, S16, U32, S32, FLOAT32 and single bits, all four byte orders, scale and offset.

⇄

BACnet/IP or MS/TP

BACnet/IP over Ethernet or Wi-Fi — or BACnet MS/TP master on one RS485 channel while the other channel polls Modbus. Chosen in the configuration, same hardware.

⇅

Commands from the BMS

Analog and Binary Values are commandable with the standard 16-level priority array. Commands are written to the Modbus device; when the BMS releases control, the object shows the device's own value again.

◉

COV and fault status

The BMS can subscribe to changes (COV) instead of polling. When a Modbus device stops answering, its objects report a communication fault in Reliability and Status_Flags — visible in the BMS right away.

⚡

Commissioning in minutes

Edit the point list in the browser or as a CSV file in Excel and copy it from site to site. Live values and communication status for every point. Neighbouring registers are read in one request, keeping the RS485 bus light.

☁

Secure remote service

Secure Boot and encrypted storage on the device, HTTPS web interface and JSON API. Vectrolink Cloud gives remote access and firmware updates without VPN or port forwarding — sold as a separate subscription.

Use cases

Energy metering

Modbus meters in a BACnet BMS

Electricity, heat and water meters are usually Modbus-only, even in BACnet buildings. vMBT-02 reads them on RS485 and hands the BMS ready BACnet objects in kWh, kW or m³ — with COV, so trend logs stay current without heavy polling.

HVAC equipment

Heat pumps, AHUs and drives

Equipment with a Modbus interface becomes part of the BMS: temperatures and states as inputs, set-points and on/off as commandable values with priorities, so schedules and operator overrides work as with any BACnet controller.

MS/TP sites

Joining an existing MS/TP trunk

Where the BMS runs on BACnet MS/TP, vMBT-02 joins the trunk as a master node on one RS485 channel and polls the Modbus devices on the other. No IP network needed in the plant room.

System integrators

Same job, many buildings

Prepare the point list once as a CSV file, adapt slave addresses and instances in Excel, and load it into the next gateway. Remote access through Vectrolink Cloud saves site visits during commissioning and service.

Technical Specifications

BACnet BACnet/IP (UDP 47808, configurable) or BACnet MS/TP master (9600 – 115 200 bps, MAC 0–127) · protocol revision 16
BACnet objects Analog Input, Analog Value, Binary Input, Binary Value — up to 500 points · priority array on AV/BV
BACnet services Who-Is/I-Am, Who-Has/I-Have, ReadProperty, ReadPropertyMultiple, WriteProperty, SubscribeCOV, DeviceCommunicationControl
Modbus RTU master · read FC01–FC04 · write FC05, FC06, FC16 · U16/S16/U32/S32/FLOAT32, bits · 4 byte orders · scale/offset
RS485 Channels 2× galvanically isolated · 1 200 – 115 200 bps · parity None / Even / Odd · one channel can carry MS/TP
Connectivity Wi-Fi 802.11 b/g/n 2.4 GHz · 10/100 Mbps Ethernet
Configuration HTTPS Web UI · CSV import/export (Excel) · JSON API
Security Secure Boot · encrypted storage · HTTPS · user accounts
Remote access Web UI, API and firmware updates via Vectrolink Cloud when internet is available
Power Supply 10 – 24 V DC, < 3 W
Protection IP20 · Reverse-polarity protected
Temperature −20 °C to +70 °C operating
Housing DIN-rail (35 mm TS), 2-module width

Documentation: Client Manual (PDF) · API Reference (PDF)

Interested in vMBT-02?

vMBT-02 is available now. Ask us for a quote — or tell us about your Modbus devices and BMS, and we will check the integration with you.